Chicago Metallic® 4000 Tempra™ 9/16" Exposed grid ceiling system is available in both intermediate and heavy-duty designs, both non-fire rated and fire rated construction, and is built with HDG 30 steel.This drop ceiling grid features both seismically approved stab-end cross tees and demountable hook-end cross tees. Chicago Metallic™ grid systems are third party certified to meet ASTM standards and are listed with ICCES Evaluation Services, see report ESR-2631 for more information.

Performance Properties:
-Grid system is available in both intermediate and heavy duty designs, with either stab-end and hook-end cross tees
-Fire rated components are designed with expansion reliefs, making it suitable for fire-rated ceiling assemblies
-Suspension system in (4000) non-fire rated, (4050) fire rated, and in (4000HRC) high recycled content
-Sustainable: Minimum 25% recycled content,100% locally recyclable
-Chicago Metallic® suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E1264-08

Available in the following standard colors, Rockfon® Color-all™ colors, and RAL color options.

Grid Colors

    • 01 White
      01 White
    • 08 Black
      08 Black
    • 44 Satin Silver
      44 Satin Silver
    • Color-all
      Color-all
    • RAL
      RAL

Material

ASTM C 635 Heavy Duty (HD) and Intermediate Duty (ID) main tee classifications; commercial quality steel, G30 hot-dip galvanized body and cap, 9/16" width, 1-1/2" and 1-5/8" heights.
Note: A metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed.

Application Areas

Hospitals, hospitality, retail, airports, transit, galleries, and offices.
Back

Product Performance

Load Bearing Expand to view deflection table
 Component Load Test Data and Material
Main Tee Length Allowable Load per ASTM C635
Hanger Spacing
4' 5' 6'
4000 144" ID 6.4 3.8
4040 144" HD 8.8 5.3
4040 HRC 144" HD 8.8
4050 144" ID
Cross Tee Length 2' 3' 4' 5'
4022 24" 24.5 ▲
4022 HRC 24" 24.5 ▲
4032 24" 24.5 ▲
4052 24" 45.0 ▲
4014 48" 12.9
4014 HRC 48" 12.9
4034 48" 12.9
4054 48" 12.9
4015 60" 6.5
4017 72" 27.3 •▲
4018 96" 12.5 •▲

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.
• Wire at mid-point of member
Note: For 6’ and 8’ cross tee spans with no hanger support at mid-point of member, please contact Technical Ser

 Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
4040CH 4014CZ 4040CH 4014HRCZ 4000CZ 4015CH 4001CH 4015CH 4050.01CH 4054.01CH
1’ x 4’ 42.4 42.4 45.6
2’ x 2’ 38.8 38.8 38.8
2’ x 4’ 49.6 49.6 44.0 ▲ 49.6
20” x 48” 35.0 35.0
20” x 60” 35.0 35.0

▲ Limited by safety factor of 2.

Fire Rated Assemblies Hanger Positions for Fire Rated Situations
This illustrates hanger positions for single fixtures in a field and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area.
Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations
This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures.
Environment Materials and Resources (MR)
-Waste Management Planning
-Interiors Life Cycle Impact Reduction
-Environmental Product Declarations
-Sourcing of Raw Materials
-Material Ingredients
-Waste Management
Indoor Environmental Quality (EQ)
-Low-Emitting Materials
-Interior Lighting
-Acoustic Performance
Back
 Component Load Test Data and Material
Main Tee Length Allowable Load per ASTM C635
Hanger Spacing
4' 5' 6'
4000 144" ID 6.4 3.8
4040 144" HD 8.8 5.3
4040 HRC 144" HD 8.8
4050 144" ID
Cross Tee Length 2' 3' 4' 5'
4022 24" 24.5 ▲
4022 HRC 24" 24.5 ▲
4032 24" 24.5 ▲
4052 24" 45.0 ▲
4014 48" 12.9
4014 HRC 48" 12.9
4034 48" 12.9
4054 48" 12.9
4015 60" 6.5
4017 72" 27.3 •▲
4018 96" 12.5 •▲

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.
• Wire at mid-point of member
Note: For 6’ and 8’ cross tee spans with no hanger support at mid-point of member, please contact Technical Ser

 Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
4040CH 4014CZ 4040CH 4014HRCZ 4000CZ 4015CH 4001CH 4015CH 4050.01CH 4054.01CH
1’ x 4’ 42.4 42.4 45.6
2’ x 2’ 38.8 38.8 38.8
2’ x 4’ 49.6 49.6 44.0 ▲ 49.6
20” x 48” 35.0 35.0
20” x 60” 35.0 35.0

▲ Limited by safety factor of 2.

Back
Back
Back

Accessories

148780_r1_ROC_GridDS_EPSFiles_SingleImages_4000

Compatible Tile Edge Types

Compatible tile edge type image example

4000/4050/4000HRC Systems

Back

Profiles and Accessories

Main Runners

Component Length Height Face Width Slot Spacing Fire Rated Seismic Recycled Content Percentage Slotting Class Duty HDG Coating HRC Packaging  
Main Runners RFN-NA  
Main Runner_4000.jpg 144" 1-5/8" 9/16" 6" OC C, DEF 25% 6" OC, HD HD G30 See Packaging Dimensions
Main Runner_4000.jpg 120" 1-5/8" 9/16" 10" OC C 25% 10" OC, ID ID G30 See Packaging Dimensions
Main Runner_4000.jpg 144" 1-5/8" 9/16" 6" OC C 25% 6" OC, ID ID G30 See Packaging Dimensions
Main Runner_4000.jpg 144" 1-5/8" 9/16" 6" OC Fire Rated C 25% 6" OC, ID ID G30 See Packaging Dimensions
Main Runner_4000.jpg 144" 1-5/8" 9/16" Slots 6" OC C, DEF 65% Slots 6" OC, HD HD G30 HRC See Packaging Dimensions

Cross Tees

Component Length Height Face Width Slot Spacing Fire Rated Seismic Recycled Content Percentage Slotting Class Grid Coupling Type HDG Coating HRC Packaging  
Cross Tees RFN-NA  
Cross Tee_4000.jpg 4" 1-1/2" 9/16" No Slots C, DEF 25% No Slots Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 20" 1-1/2" 9/16" No Slots C, DEF 25% No Slots Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 48" 1-1/2" 9/16" 24" OC C 25% 24" OC Hook-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 6" 1-1/2" 9/16" No Slots C, DEF 25% No Slots Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 96" 1-1/2" 9/16" 24" OC C, DEF 25% 24" OC Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 72" 1-1/2" 9/16" 24" OC C, DEF 25% 24" OC Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 24" 1-1/2" 9/16" No Slots C, DEF 25% No Slots Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 48" 1-1/2" 9/16" 12" OC C, DEF 25% 12" OC Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 60" 1-1/2" 9/16" 10" OC C, DEF 25% 10" OC Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 24" 1-1/2" 9/16" No Slots C 25% No Slots Hook-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 48" 1-3/4" 9/16" 12" OC Fire Rated C, DEF 25% 12" OC Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 24" 1-3/4" 9/16" No Slots Fire Rated C, DEF 25% No Slots Stab-End G30 See Packaging Dimensions
Cross Tee_4000.jpg 48" 1-5/8" 9/16" Slots 12" OC C, DEF 65% Slots 12" OC Stab-End G30 HRC See Packaging Dimensions
Cross Tee_4000.jpg 24" 1-5/8" 9/16" No Slots C, DEF 65% No Slots Stab-End G30 HRC See Packaging Dimensions

Wall Angles & Channels

Component Length Height Face Width Seismic Recycled Content Percentage HRC Packaging  
Wall Angles RFN-NA  
Wall Angles_830.jpg 144" 15/16" 15/16" C, DEF 25% See Packaging Dimensions
Wall Angles_830.jpg 144" 15/16" 15/16" C, DEF 25% See Packaging Dimensions
Wall Angle_G90.jpg 144" 9/16" 15/16" C, DEF 25% See Packaging Dimensions
Wall Angles_830.jpg 144" 15/16" 15/16" C, DEF 65% HRC See Packaging Dimensions
Wall Angle_G90.jpg 144" 9/16" 15/16" C, DEF 65% HRC See Packaging Dimensions

Shadow Moldings

Component Length Height Face Width Seismic Recycled Content Percentage Slotting Class Packaging  
Shadow Moldings RFN-NA  
Wall Moldings_200.jpg 120" 3/4" 3/4" C 25% 3/8" Reveal See Packaging Dimensions
Wall Moldings_200.jpg 120" 3/4" 3/4" C 25% 3/4" Reveal See Packaging Dimensions
Wall Moldings_200.jpg 120" 15/16" 9/16" C 25% 3/8" Reveal See Packaging Dimensions
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Back
Note: Cross tees are override design, with stab-in end detail, unless noted otherwise. Hook end tees are suitable for seismic areas 1 and 2 only. Butt-cut tees are used for true, flat panel installation, i.e., metal panels. Wires required at mid point for loads exceeding weight of Rockfon tile.
Back

Find the support you need.

search

Contact Type

Showing
Offices & Factories near you