Back

Grid Colors

    • 01 White
      01 White
    • 08 White w/ Black Reveal
      08 White w/ Black Reveal
    • 44 Satin Silver
      44 Satin Silver

Case studies featuring Chicago Metallic® 4500 Ultraline™ 9/16"

NA, Perkins Eastman Chicago Studio, Office, Renovation, WELL Platinum, Perkins Eastman, Sonar, Stone Wool Ceiling, Chicago Metallic 4500 Ultraline, Suspension Grid

Project: Perkins Eastman Chicago Studio

See full project
NA, Perkins Eastman Chicago Studio, Office, Renovation, WELL Platinum, Perkins Eastman, Sonar, Stone Wool Ceiling, Chicago Metallic 4500 Ultraline, Suspension Grid

Project: Perkins Eastman Chicago Studio

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Rockfon® Spanair® Torsion Spring concealed metal ceiling panels, Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system, Rockfon® Infinity™ Perimeter Trim

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Rockfon® Spanair® Torsion Spring concealed metal ceiling panels, Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system, Rockfon® Infinity™ Perimeter Trim

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system, Rockfon® Infinity™ Perimeter Trim

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system, Rockfon® Infinity™ Perimeter Trim

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system, Rockfon® Infinity™ Perimeter Trim

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, Kaiser Permanente Mission Bay Medical Offices, KMD Architects, Rockfon Artic®, Rockfon® Spanair® Torsion Spring concealed metal ceiling panels; Chicago Metallic® Ultraline™ and 1200 Series 15/16-inch ceiling suspension system; Rockfon® Infinity™ Perimeter Trim

Project: Kaiser Permanente, Mission Bay Medical Offices

See full project
NA, National Association of Broadcasters Headquarters, Tropic, 4500 Ultraline

Project: National Association of Broadcasters Headquarters

See full project
NA, National Association of Broadcasters Headquarters, Tropic, 4500 Ultraline

Project: National Association of Broadcasters Headquarters

See full project
NA, National Association of Broadcasters Headquarters, Tropic, 4500 Ultraline

Project: National Association of Broadcasters Headquarters

See full project
NA, National Association of Broadcasters Headquarters, Tropic, 4500 Ultraline

Project: National Association of Broadcasters Headquarters

See full project
NA, Waste Management Corporate Headquarters, Perkins & Will, Office, Sonar, Stone Wool Ceiling Tiles, Ultraline, Suspension Grid, Infinity, Perimeter Trim, LEED Platinum

Project: Waste Management Corporate Headquarters

See full project
NA, Waste Management Corporate Headquarters, Perkins & Will, Office, Sonar, Stone Wool Ceiling Tiles, Ultraline, Suspension Grid, Infinity, Perimeter Trim, LEED Platinum

Project: Waste Management Corporate Headquarters

See full project
NA, Waste Management Corporate Headquarters, Perkins & Will, Office, Sonar, Stone Wool Ceiling Tiles, Ultraline, Suspension Grid, Infinity, Perimeter Trim, LEED Platinum

Project: Waste Management Corporate Headquarters

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Education, Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will,  LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, Education, LEED® Gold Certified, Sonar SLT 2'x4', Tropic SL 2'x4', Medical Standard SL 2'x4', Stone Wool Ceilings, Chicago Metallic 1200 Seismic, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold Certified, Sonar SLT 2'x4', Tropic SL 2'x4', Medical Standard SL 2'x4', Stone Wool Ceilings, Chicago Metallic 1200 Seismic, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold Certified, Sonar SLT 2'x4', Tropic SL 2'x4', Medical Standard SL 2'x4', Stone Wool Ceilings, Chicago Metallic 1200 Seismic, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold Certified, Sonar SLT 2'x4', Tropic SL 2'x4', Medical Standard SL 2'x4', Stone Wool Ceilings, Chicago Metallic 1200 Seismic, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC), Perkins&Will, LEED® Gold- Certified, Sonar SLN 2'x8', Stone Wool Ceilings, Chicago Metallic 4500 Ultraline with 1/4" Reveal, Suspension Grid

Project: Toronto Metropolitan University, Daphne Cockwell Health Sciences Complex (DCHSC)

See full project
NA, Atlanta Braves CoolToday Park, Artic SLN (E-Edge) 2x2, 4500 Ultraline, Planostile Snap-In 2x2 in Satin Silver, Locker Room, Leisure, Fawley Bryant Architecture

Project: Atlanta Braves Spring Training Complex

See full project
Back

Product Performance

Load Bearing Expand to view deflection table
 Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
4500.01 4514.01 4500.01 4524.01 4530.01 4514.01 4550.01 4564.01 4550.01 4568.01
2’ x 2’ 42.4 42.4 43.2 43.2
2’ x 4’ 58.4 58.4 58.4 67.2 67.2
 Component Load Test Data and Material
Main Tee Length Allowable Load per ASTM C635
Hanger Spacing
4' 5' 6'
Cross Tee Length 2' 4' 5' 6'
4500 144" ID 7.7 4.6
4501 120" ID 7.7 4.6
4502 120" ID 7.7 4.6
4503 120" ID 7.7 4.6
4512 24" 55.0▲
4512.01HRC 24" 55.0▲
4514 48" 14.6
4514.01HRC 48" 14.5
4515 60" 7.7
4516 72" 4.6
4518 48" 14.6
4519 60" 7.7
4521 60" 7.7
4524 48" 13.1
4528 96"
4530 144" HD 9.3 5.6
4530.01HRC 144" HD 9.3 5.6
4531 120" HD 9.3 5.6
4540 144" ID 7.7 4.6
4550 144" ID 9.3 5.6
4560 144" HD 9.3 5.6
4562 24" 55.0▲
4564 48" 14.5
4568 48" 14.5

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.

Fire Rated Assemblies Hanger Positions for Fire Rated Situations
This illustrates hanger positions for single fixtures in a field and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area.
Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations
This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures.
Environment Materials and Resources (MR)
-Waste Management Planning
-Interiors Life Cycle Impact Reduction
-Environmental Product Declarations
-Sourcing of Raw Materials
-Material Ingredients
-Waste Management
Indoor Environmental Quality (EQ)
-Low-Emitting Materials
-Interior Lighting
-Acoustic Performance
Back
 Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
4500.01 4514.01 4500.01 4524.01 4530.01 4514.01 4550.01 4564.01 4550.01 4568.01
2’ x 2’ 42.4 42.4 43.2 43.2
2’ x 4’ 58.4 58.4 58.4 67.2 67.2
 Component Load Test Data and Material
Main Tee Length Allowable Load per ASTM C635
Hanger Spacing
4' 5' 6'
Cross Tee Length 2' 4' 5' 6'
4500 144" ID 7.7 4.6
4501 120" ID 7.7 4.6
4502 120" ID 7.7 4.6
4503 120" ID 7.7 4.6
4512 24" 55.0▲
4512.01HRC 24" 55.0▲
4514 48" 14.6
4514.01HRC 48" 14.5
4515 60" 7.7
4516 72" 4.6
4518 48" 14.6
4519 60" 7.7
4521 60" 7.7
4524 48" 13.1
4528 96"
4530 144" HD 9.3 5.6
4530.01HRC 144" HD 9.3 5.6
4531 120" HD 9.3 5.6
4540 144" ID 7.7 4.6
4550 144" ID 9.3 5.6
4560 144" HD 9.3 5.6
4562 24" 55.0▲
4564 48" 14.5
4568 48" 14.5

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.

Back
Back
Back

Accessories

148780_r1_ROC_GridDS_EPSFiles_SingleImages_4500

Compatible Tile Edge Types

Compatible tile edge type image example

4500/4550/4500HRC Systems

Back

Resources

 

 

print pdf
icon
Rockfon Seismic Relief Brochure
Rockfon Seismic Relief Brochure

pdf
icon
Rockfon Seismic Relief Brochure FR
Rockfon Seismic Relief Brochure FR

pdf
icon
EPD Steel CISCA
EPD Steel CISCA

pdf
icon
Chicago Metallic® 4500 Ultraline™ 9/16" Exposed Datasheet
Chicago Metallic® 4500 Ultraline™ 9/16" Exposed Datasheet

pdf
icon
Chicago Metallic® 4500 Ultraline™ 9/16" Exposed Datasheet FR
Chicago Metallic® 4500 Ultraline™ 9/16" Exposed Datasheet FR

pdf
icon
Rockfon® Accessories Datasheets
Rockfon® Accessories Datasheets

pdf
icon
Rockfon® Accessories DataSheet FR
Rockfon® Accessories DataSheet FR

pdf
icon
Rockfon Using 12 Gauge Hanger Wire Installation Guide
Rockfon Using 12 Gauge Hanger Wire Installation Guide

pdf
icon
Rockfon Seismic Perimeter Details: Tech Note
Rockfon Seismic Perimeter Details: Tech Note

pdf
icon
Rockfon Fire Rated Ceiling Assemblies: Tech Note
Rockfon Fire Rated Ceiling Assemblies: Tech Note

pdf
icon
Rockfon Product Cleaning and Maintenance Tech Note
Rockfon Product Cleaning and Maintenance Tech Note

pdf
icon
Rockfon Product Cleaning & Maintenance Tech Note FR
Rockfon Product Cleaning & Maintenance Tech Note FR

pdf
icon
Chicago Metallic 4500 Ultraline 9-16 Exposed With 1-4 Reveal Specification
Chicago Metallic 4500 Ultraline 9-16 Exposed With 1-4 Reveal Specification

pdf
icon
Chicago Metallic 4500 Ultraline 9-16 Exposed With 1-4 Reveal CDN Specification
Chicago Metallic 4500 Ultraline 9-16 Exposed With 1-4 Reveal CDN Specification

pdf
icon
Chicago Metallic 4500 Ultraline HRCmax 9-16 Exposed With 1-4 Reveal Specification
Chicago Metallic 4500 Ultraline HRCmax 9-16 Exposed With 1-4 Reveal Specification

pdf
icon
Chicago Metallic 4500 Ultraline HRCmax 9-16 Exposed With 1-4 Reveal CDN Specification
Chicago Metallic 4500 Ultraline HRCmax 9-16 Exposed With 1-4 Reveal CDN Specification

pdf
icon
Chicago Metallic 4550 Ultraline 9-16 Exposed With 1-4 Reveal Specification
Chicago Metallic 4550 Ultraline 9-16 Exposed With 1-4 Reveal Specification

pdf
icon
Chicago Metallic 4550 Ultraline 9-16 Exposed With 1-4 Reveal CDN Specification
Chicago Metallic 4550 Ultraline 9-16 Exposed With 1-4 Reveal CDN Specification

pdf
icon
Rockfon 40 Year Suspension System Warranty
Rockfon 40 Year Suspension System Warranty

pdf
icon
Sample Order Form: Chicago Metallic Ultraline 4500
Sample Order Form: Chicago Metallic Ultraline 4500

Click 'PDF' to download and customize your grid system sample kit.

pdf
Back